indisposaled
Aug. 18th, 2005 10:43 am![[personal profile]](https://www.dreamwidth.org/img/silk/identity/user.png)
So I cleared out the area under the sink and took a closer look at the disposal (I've always called them disposal's but most of the hardware website seem to call them diposERs, according to dictionary.com I'm right and they're wrong nyah-nyah). First thing I noticed is there is a small puddle under it. Not good but all sinks I've ever seen leak a little occasionally so I wasn;t too worried.
Found the reset button for the disposal
pi3832 mentioned. Pushed it and it hummed for a bit then popped again. At least it's not the house wiring (my dark nightmare), it's the unit itself. Got up and waggled a plunger handle in there and ran water to see if I could free it but when I pushed the reset it just hummed again and then popped. This time I noticed there was a drip from the bottom of the unit, but not from the plumbing connection point as I had been expecting but from an inspection plate.
I looked around the house for 15 minutes trying to find a flat bladed screw driver to take it off (who the hell uses flat screws anymore?) and finally had to use a screwtip in a nut driver. Took the plate off and confirmed that the leaking was coming from inside the unit. Pushed the reset button again and it hummed for a while then I saw a flash and it stopped. So something is shorting out inside. I was about to poke at the wire connections to the house romax the access plate was there for but then realized the line was still hot, there thing was damp and I knew it was shorting and apparently made my save against stupidity roll.
Found the reset button for the disposal
![[livejournal.com profile]](https://www.dreamwidth.org/img/external/lj-userinfo.gif)
I looked around the house for 15 minutes trying to find a flat bladed screw driver to take it off (who the hell uses flat screws anymore?) and finally had to use a screwtip in a nut driver. Took the plate off and confirmed that the leaking was coming from inside the unit. Pushed the reset button again and it hummed for a while then I saw a flash and it stopped. So something is shorting out inside. I was about to poke at the wire connections to the house romax the access plate was there for but then realized the line was still hot, there thing was damp and I knew it was shorting and apparently made my save against stupidity roll.
suggesting
Date: 2005-08-18 05:40 pm (UTC)no subject
Date: 2005-08-18 05:42 pm (UTC)Yup, I'll be plagarizing that.
no subject
Date: 2005-08-18 10:05 pm (UTC)